Applications
ENARDO Detonation Flame Arrestors provide protection against flame propagation in piping systems that are manifolded or have long run-up distances. Our design is unique in the ability to provide larger flame channels that allow for less frequent plugging and easier cleaning when service is required—both of which translate to less down time.
ENARDO Detonation Flame Arrestors are bi-directional and proven to stop an ignited flammable vapor mixture approaching from either direction and traveling at subsonic or supersonic velocities. Our patented element offers maximum flow to pressure drop characteristics.
Features
Series 7 Deflagration Arrestors |
|||
|
Model |
Group IIA (D) |
Group IIB3(C) |
|
| ATEX |
Factory Mutual |
ATEX |
|
70402 |
X |
X |
X |
70602 |
X |
|
X |
70603 |
X |
X |
X |
70803 |
X |
|
X |
70804 |
X |
X |
X |
71204 |
X |
|
X |
71206 |
X |
X |
X |
71606 |
X |
|
X |
71608 |
X |
X |
X |
72008 |
X |
|
X |
72010 |
X |
X |
X |
72410 |
X |
|
X |
72412 |
X |
X |
X |
* Applicable approvals must be specified prior to manufacture and will be indicated on the product nameplate.
Free Vent Flame Arrestor (FVFA) |
||
| Model |
Group IIA (D) |
Group IIB3(C) |
| ATEX |
ATEX |
|
402 |
X |
X |
602 |
X |
X |
603 |
X |
X |
803 |
X |
X |
804 |
X |
X |
1204 |
X |
X |
1206 |
X |
X |
1606 |
X |
X |
1608 |
X |
X |
2008 |
X |
X |
2010 |
X |
X |
2410 |
X |
X |
2412 |
X |
X |
* Applicable approvals must be specified prior to manufacture and will be indicated on the product nameplate.
Detonation Flame Arrestor - Group D (IIA) |
|||
| Model |
Type of Detonation |
ATEX |
U.S. Coast Guard and |
DFA 402 |
UNSTABLE |
X |
|
DFA 602 |
UNSTABLE |
X |
X |
DFA 603 |
UNSTABLE |
X |
|
DFA 803 |
UNSTABLE |
X |
X |
DFA 804 |
UNSTABLE |
X |
|
DFA 1004 |
UNSTABLE |
|
X |
DFA 1204 |
UNSTABLE |
X |
X |
DFA 1206 |
UNSTABLE |
X |
X |
DFA 1608 |
UNSTABLE |
X |
X |
DFA 2010 |
UNSTABLE |
X |
X |
DFA 2412 |
UNSTABLE |
X |
X |
DFA 2814 |
UNSTABLE |
|
X |
DFA 3016 |
UNSTABLE |
|
X |
DFA 3418 |
UNSTABLE |
|
X |
DFA 3620 |
UNSTABLE |
|
X |
Detonation Flame Arrestor - Group C (IIB3) |
|||
| Model |
Type of Detonation |
ATEX |
U.S. Coast Guard and |
DFA 402 |
UNSTABLE |
X |
|
DFA 602 |
UNSTABLE |
X |
X |
DFA 603 |
UNSTABLE |
X |
|
DFA 803 |
UNSTABLE |
X |
X |
DFA 804 |
UNSTABLE |
X |
|
DFA 1004 |
UNSTABLE |
|
X |
DFA 1204 |
UNSTABLE |
X |
X |
DFA 1206 |
UNSTABLE |
X |
X |
DFA 1608 |
UNSTABLE |
X |
X |
DFA 2010 |
UNSTABLE |
X |
X |
DFA 2412 |
UNSTABLE |
X |
X |
DFA 2814 |
UNSTABLE |
|
X |
DFA 3016 |
UNSTABLE |
|
X |
DFA 3418 |
UNSTABLE |
|
X |
DFA 3620 |
UNSTABLE |
|
X |
* Applicable approvals must be specified prior to manufacture and will be indicated on the product nameplate.
** Endurance burn rating applicable only to concentric configuration.
Choosing the proper flame arrestor is critical to the safety of equipment and personnel. Consult the table below to select the product which best fits your needs, taking into account vent/piping layout and gas group.
Including US Coast Guard and ATEX/US Coast Guard certified detonation arrestors
NEC Group "D" or IEC Group IIA Gases |
||||
| Parameters | End-of-Line FVFA & SVFA |
In-Line (Standard) S7 HP & IL |
In-Line HP Deflag. S8 |
Detonation Arrestor DFA |
| Length of pipe between the arrestor and the ignition source without bends | (Mounted on end of pipe) | 20 feet (6 meters) |
60 feet (18 meters) |
Unlimited |
| Length of pipe between the arrestor and the ignition source with one 90° bend | (Mounted on end of pipe) | 20 feet (6 meters) |
60 feet (18 meters) |
Unlimited |
| Length of pipe between the arrestor and the ignition source with multiple bends | (Mounted on end of pipe) | Not recommended with multiple bends | Not recommended with multiple bends | Unlimited |
| Flame stabilization at stoichiometric mixture and ambient temperature not to exceed 140°F (60°C) * | 5 minutes (minimum) |
5 minutes (minimum) 30 minutes (Factory Mutual Approved units) |
15 minutes (minimum) |
2 hours (concentric) |
| Operating Pressure | Atmospheric | 15.4 psia (106 kPa) |
19.7 psia (134 kPa) |
Conc. 3"-12" (22.7 psia) (75-300mm) 157 kPa Conc. 2", 14"-20" (20.7 psia) (50, 350-500mm) 143 kPa |
NEC Group "C" or IEC Group IIB3 Gases |
||||
| Parameters | End-of-Line FVFA & SVFA |
In-Line (Standard) S7 HP & IL |
In-Line HP Deflag. S8 |
Detonation Arrestor DFA |
| Length of pipe between the arrestor and the ignition source without bends | (Mounted on end of pipe) | 6 feet (2 meters) (open-ended pipe) |
35 feet (10.6 meters) |
Unlimited |
| Length of pipe between the arrestor and the ignition source with one 90° bend | (Mounted on end of pipe) | 6 feet (2 meters) (open-ended pipe) |
35 feet (10.6 meters) |
Unlimited |
| Length of pipe between the arrestor and the ignition source with multiple bends | (Mounted on end of pipe) | Not recommended with multiple bends | Not recommended with multiple bends | Unlimited |
| Flame stabilization at stoichiometric mixture and ambient temperature not to exceed 140°F (60°C) * | 5 minutes (minimum) |
5 minutes (minimum) |
15 minutes (minimum) |
15 minutes (minimum) |
| Operating Pressure | Atmospheric | 15.4 psia (106 kPa) |
16.7 psia (115 kPa) |
Conc. (2"-20") 20.7 psia (50-500mm) 143 kPa Ecc. (3"-20") 18.7 psia (75-500mm) 129 kPa |
NEC Group "B" or IEC Group IIC Gases (Except Acetylene) |
||||
| Parameters | End-of-Line FVFA & SVFA |
In-Line (Standard) S7 HP & IL |
In-Line HP Deflag. S8 |
Detonation Arrestor DFA |
| Length of pipe between the arrestor and the ignition source without bends | (Mounted on end of pipe) | 4 feet (1.2 meters) (open-ended pipe) |
15 feet (4.5 meters) |
Unlimited |
| Length of pipe between the arrestor and the ignition source with one 90° bend | (Mounted on end of pipe) | Not recommended with a bend | 15 feet (4.5 meters) |
Unlimited |
| Length of pipe between the arrestor and the ignition source with multiple bends | (Mounted on end of pipe) | Not recommended with multiple bends | Not recommended with multiple bends | Unlimited |
| Flame stabilization at stoichiometric mixture and ambient temperature not to exceed 140°F (60°C) * | 2 minutes (minimum) |
2 minutes (minimum) |
15 minutes (minimum) |
15 minutes (minimum) |
| Operating Pressure | Atmospheric | 15.4 psia (106 kPa) |
16.7 psia (115 kPa) |
Conc. 2"-6" (17.7 psia) (50mm-150mm) 122 kPa |
* Unlimited burning should not be allowed in any flame arrestor regardless of its burn time rating. We recommend the use of flame sensors, along with an appropriate means of extinguishing the fire, in any situation where a stabilized burn may occur.
See above for information on ATEX/US Coast Guard detonation arrestor selection criteria.
IEC Group IIA Gases or NEC Group "D" |
||||
| Parameters | End-of-Line FVFA |
In-Line (Standard) S7 HP & IL |
Detonation Arrestor DFA | |
| Length of pipe between the arrestor and the ignition source. | (Mounted on end of pipe) | 2" (50 mm) - 6.5 ft (2 m) 3" (75 mm) - 7.5 ft (2.3 m) 4" (100 mm) - 10 ft (3 m) 6" (150 mm) - 13.1 ft (4 m) 8" (200 mm) - 13.3 ft (4 m) 10" (250 mm) - 16.6 ft (5 m) 12" (300 mm) - 19.7 ft (6 m) |
2" - 12" (50mm-300mm) Unrestricted (Designed for Unstable Detonations) |
|
| Flame stabilization at stoichiometric mixture and ambient temperature not to exceed 140°F (60°C) | Short Time Burn Rating | Short Time Burn Rating | Short Time Burn Rating | |
| Operating Pressure | Atmospheric | 15.95 psia (110 kPa) |
2"-6" 17.7 psia (50 mm-150 mm 122 kPa) 8 - 12" 16.9 psia (200 mm - 300 mm 116.5 kPa) |
|
IEC Group IIB3 Gases or NEC Group "C" |
||||
| Length of pipe between the arrestor and the ignition source. | (Mounted on end of pipe) | 2" (50 mm) - 8.3 ft (2.5 m) 3" (75 mm) - 12.5 ft (3.8 m) 4" (100 mm) - 16.6 ft (5 m) 6" (150 mm) - 25 ft (7.6 m) 8" (200 mm) - 33.3 ft (10.16 m) 10" (250 mm) - 39.3 ft (12 m) 12" (300 mm) - 39.4 ft (12 m) |
2" - 12" (50mm-300mm) Unrestricted (Designed for Unstable Detonations) |
|
| Flame stabilization at stoichiometric mixture and ambient temperature not to exceed 140°F (60°C) | Short Time Burn Rating | Short Time Burn Rating | Short Time Burn Rating | |
| Operating Pressure | Atmospheric | 15.95 psia (110 kPa) |
17.2 psia (118.3 kPa) |
|
Gas Group Chart |
||
| Group A | Group D (continued) | |
| Acetlyene | Ethanol (ethyl alcohol) | |
| Ethyl acetate | ||
| Group B (IIC) | Ethyl acrylate | |
| Butadiene | Ethylene dichloride | |
| Ethylene oxide | Gasoline | |
| Hydrogen Manufactured gases containing more than 30% Hydrogen (by volume) |
Heptanes | |
| Propylene oxide | Hexanes | |
| Propyl nitrate | Isoprene | |
| Methane (natural gas) | ||
| Group C (IIB3) | Methyl acrylate | |
| Acetaldhyde | Methylamine | |
| Cyclopropane | Methyl ethyl ketone | |
| Diethyl ether | Methyl mercaptan | |
| Dimethyl hydrazine | 3-Methyl-1-butanol (isoamyl alcohhol) | |
| Ethylene | Methyl isobutyl ketone | |
| Hydrogen sulfide | 2-Methyl-1-propanol (isobutyl alcohol) | |
| * Methanol (methyl alcohol) | 2-Methyl-2-propanol (tertiary butyl alcohol) | |
| Methyl mercaptan | Naphtha (petroleum) | |
| Unisymmetrical dimethyl hydrazine (UDMN) | N-Propyl acetate | |
| Octanes | ||
| Group D (IIA) | Pentanes | |
| Acetone | 1-Pentanol (amyl alcohol) | |
| Acrylonitrile | Propane | |
| Ammonia | 1-Propanol (propyl alcohol) | |
| Benzene | 2-Propanol (isopropyl alcohol) | |
| Butylene | Propylene | |
| 1-Butanol (butyl alcohol) | Styrene | |
| 2-Butanol (secondary butyl alcohol) | Toluene | |
| Cyclohexane | Turpentine | |
| N-Butyle acetate | Vinyl acetate | |
| Isobutyl acetate | Vinyl chloride | |
| Ethane | Xylenes | |
Applications
ENARDO Free Vent Flame Arrestors (FVFA) are designed to allow free venting in combination with flame protection for vertical vent applications. These arrestors are installed at the top of an atmospheric vent line or storage tank. They are typically used for end-of-the-line applications when the system operating pressure is near atmospheric levels and when there is minimal probability of a flame stabilizing on the flame arrestor element for an extended period.
Features
Applications
ENARDO Series 7 In-Line Flame Arrestors are designed to stop the propagation of confined low-pressure deflagrations. The Series 7 is typically used for end-of-line and near end-of-line applications when the system operating pressure is near atmospheric levels and when there is minimal probability of a flame stabilizing on the flame arrestor element for an extended period.
Features
Applications
ENARDO Series 8 High-Pressure Deflagration Arrestor is designed to protect against high velocity and pressure flame fronts inherent in applications beyond the performance range of a standard flame arrestor but not yet to the detonation phase of flame development. The Series 8 surpasses standard flame arrestors for applications that include extended lengths of pipe with one bend, elevated operating pressures, and extended flame stabilization on the flame cell element.
Features
Applications
ENARDO Vent Stack Flame Arrestors are designed to allow free venting in combination with flame protection for vertical vent applications. The arrestor is installed at the top of an atmospheric vent line or storage tank. It is typically used for end-of-line applications when the system operating pressure is near atmospheric levels and when there is minimal probability of a flame stabilizing on the flame arrestor element for an extended period.
Features
Applications
ENARDO Threaded In-Line Flame Arrestors are typically used for end-of-line and near end-of-line applications when the system operating pressure is near atmospheric levels, and when there is minimal probability of a flame stabilizing on the flame arrestor element for an extended period. Typical applications include small fuel-assist lines, waste gas and small instrumentation lines.
Features